go-serial — Cross-Platform Serial Port (UART, RS-232 & RS-485) Library for Go (Golang)

Go Version Go Reference License: MIT CI Status Code Coverage Latest Release

go-serial is a cross-platform serial port library for Go. Open, configure, read, write and close serial (UART) ports over RS-232 and RS-485 on Linux, macOS, Windows and the BSDs, with typed configuration, validated settings and a documented concurrency contract.

It is protocol-neutral, so you can use it for custom serial protocols, GPS and sensor modules, microcontroller consoles and Modbus RTU (a ready-made 19200 8E1 preset is included). It is also the serial layer used by go-modbus.

If you are looking for a maintained alternative to goburrow/serial, see the migration guide.

Quick links: Quick start · Comparison · Modbus RTU preset · Migration guide · FAQ


Why go-serial?

  • Simple API — serial.Open(&cfg) returns a Port with standard Read, Write and Close.
  • RS-232 and RS-485 — Optional RS-485 driver configuration (RTS control and delays) where the OS supports it.
  • Typed configuration — Constants for baud rate, data bits, stop bits and parity instead of bare integers and strings.
  • Validated settings — Invalid configuration fails at Open with serial.ErrInvalidConfig and a *serial.ConfigError that names the field, value and reason.
  • Sensible defaults — Zero values give you 9600 8N1; use the modbus package for Modbus RTU defaults (19200 8E1).
  • Clear timeouts and errors — Read timeouts return serial.ErrTimeout, detectable with errors.Is.
  • Documented concurrency and close semantics — One reader and one writer may run concurrently; ownership and Close behavior are spelled out.
  • Cross-platform — Linux, macOS, Windows, FreeBSD, NetBSD and OpenBSD.
  • Testable without hardware — A PTY loopback test runs on Linux, macOS and BSD.

Quick start

go get github.com/otfabric/go-serial

Requires Go 1.23 or later.

Open /dev/ttyUSB0 at the default 9600 8N1 and write some bytes:

package main

import (
	"log"

	"github.com/otfabric/go-serial"
)

func main() {
	cfg := serial.DefaultConfig("/dev/ttyUSB0")
	port, err := serial.Open(&cfg)
	if err != nil {
		log.Fatal(err)
	}
	defer port.Close()

	_, err = port.Write([]byte("hello"))
	if err != nil {
		log.Fatal(err)
	}
}

On Windows, use a COM port name such as COM3 as the address. See Usage for timeouts, typed configuration, RS-485 and error handling.


go-serial vs other Go serial port libraries

Several Go serial libraries exist. This table compares go-serial with bugst/go-serial (import path go.bug.st/serial) and goburrow/serial so you can choose the right one.

Capability otfabric/go-serial bugst/go-serial goburrow/serial
Open, read, write, close (RS-232/UART) ✅ ✅ ✅
Linux, macOS and Windows ✅ ✅ ✅
Read timeout with a sentinel error (ErrTimeout) ✅ ✅ ✅
Typed constants for baud, data bits, stop bits, parity ✅ partial —
Config validation errors with field, value and reason ✅ — —
RS-485 driver configuration ✅ — ✅
Modbus RTU preset (19200 8E1) ✅ — implicit default
Documented concurrency and Close contract ✅ — —
Port enumeration (list available ports) — ✅ —
USB metadata (VID/PID, serial number) — ✅ —
Modem control lines (DTR, RTS, status bits) — ✅ —
License MIT BSD-3-Clause MIT

✅ = documented feature · partial = some of it · — = not documented / not available. Based on each project's public documentation as of October 2026. If you spot an inaccuracy, please open an issue and we will correct it.

Choose go-serial if you want a small, strictly validated serial transport with typed configuration, RS-485 support and clear concurrency rules, especially as the serial layer under a Modbus RTU library, or as a replacement for goburrow/serial.

Choose bugst/go-serial if you need to list ports, read USB device metadata or control modem lines (DTR/RTS) directly. go-serial does not provide these.


Use cases

  • Modbus RTU over RS-485/RS-232 — Pair with go-modbus or any Modbus library.
  • Industrial and IoT gateways — Talk to meters, sensors and controllers over serial lines.
  • Embedded and lab tooling — Drive microcontroller consoles, GPS modules and test equipment.
  • Custom serial protocols — Build framing and parsing on top of a reliable, validated transport.

Table of Contents


What this library is

  • Generic serial transport: open, configure, read, write, and close serial ports.
  • Cross-platform: Linux, macOS, Windows, and BSD variants.
  • Protocol-neutral: no built-in protocol logic. Use it for any serial-based protocol (custom, Modbus RTU, etc.).
  • RS-485: optional RS-485 driver configuration where the OS supports it.

What this library is not

It is not a Modbus (or any other protocol) implementation. It does not handle framing, CRC, ADU/PDU, or master/slave logic. For Modbus, use a dedicated Modbus library and pass it a port opened with this library.

Migrating from goburrow/serial

Old New
github.com/goburrow/serial github.com/otfabric/go-serial
Defaults (19200, even parity) Generic defaults are now 9600 8N1. Use serial.DefaultConfig(address) for generic, or modbus.DefaultRTUConfig(address) for Modbus RTU (19200 8E1).

Behavior change: If you relied on zero-value Config defaults (19200, even parity), that behavior was Modbus-oriented. In go-serial, zero-value defaults are now generic (9600, no parity). For Modbus RTU, switch to:

cfg := modbus.DefaultRTUConfig("/dev/ttyUSB0")
port, err := serial.Open(&cfg)

Usage

Generic serial (default 9600 8N1)

package main

import (
	"log"

	"github.com/otfabric/go-serial"
)

func main() {
	cfg := serial.DefaultConfig("/dev/ttyUSB0")
	port, err := serial.Open(&cfg)
	if err != nil {
		log.Fatal(err)
	}
	defer port.Close()

	_, err = port.Write([]byte("hello"))
	if err != nil {
		log.Fatal(err)
	}
}

Modbus RTU preset (19200 8E1)

For Modbus RTU over serial, use the serial/modbus package to get standard RTU defaults, then open with the root package. modbus.DefaultModbusRTUConfig is an alias for DefaultRTUConfig.

package main

import (
	"log"

	"github.com/otfabric/go-serial"
	"github.com/otfabric/go-serial/modbus"
)

func main() {
	cfg := modbus.DefaultRTUConfig("/dev/ttyUSB0")
	port, err := serial.Open(&cfg)
	if err != nil {
		log.Fatal(err)
	}
	defer port.Close()

	// Use port with your Modbus library (framing, CRC, etc. are not in this repo).
}

Typed configuration

Config uses typed fields and constants:

cfg := serial.DefaultConfig("/dev/ttyUSB0")
cfg.BaudRate = serial.Baud115200
cfg.DataBits = serial.DataBits8
cfg.StopBits = serial.StopBits1
cfg.Parity = serial.ParityNone

Ownership, concurrency, and Close

  • Ownership — Open copies and normalizes Config. The caller owns the returned Port and must Close it. Do not use the port after Close.
  • Concurrency — One Read and one Write may run concurrently on the same Port (full-duplex). Do not run multiple concurrent readers or writers, and do not call Close concurrently with Read/Write (undefined).
  • Timeouts — Config.Timeout applies to Read on all platforms. On Windows, the same timeout is also applied to Write when Timeout > 0. On POSIX (Linux/macOS/BSD), Write has no library-applied timeout: it blocks while the driver's output buffer is full and returns only once all bytes are written (or with an error). Timeout == 0 means Read may block indefinitely until data arrives (or the underlying fd/handle is closed by the OS).
  • Close — Restores prior termios (POSIX) or DCB/timeouts (Windows) when possible, then closes the fd/handle. Closing may cause a blocked Read/Write to return an error on some platforms, but this is not a synchronized cancel API (no CancelIo / coordinated wakeup). Prefer a finite Timeout for Read, and avoid Close while I/O is in flight.
  • Hangup — On POSIX systems, Read returns io.EOF (or the OS error, such as EIO) with n == 0 once the device goes away, e.g. an unplugged USB adapter; it never returns a negative count.

Package godoc (serial.go) restates the same contract.

Timeout and error handling

Set Config.Timeout to influence blocking I/O timeout behavior. Read timeout behavior is supported across platforms; write timeout behavior may depend on the platform and driver. When a read times out, the port returns serial.ErrTimeout. Use errors.Is to detect it:

package main

import (
	"errors"
	"log"
	"time"

	"github.com/otfabric/go-serial"
)

func main() {
	cfg := serial.DefaultConfig("/dev/ttyUSB0")
	cfg.Timeout = 5 * time.Second
	port, err := serial.Open(&cfg)
	if err != nil {
		log.Fatal(err)
	}
	defer port.Close()

	buf := make([]byte, 256)
	n, err := port.Read(buf)
	if err != nil {
		if errors.Is(err, serial.ErrTimeout) {
			// read deadline exceeded, no data
			return
		}
		log.Fatal(err)
	}
	_ = n // use buf[:n]
}

Config validation

Config is validated when you call Open. Invalid settings (empty address, unsupported parity, negative timeout, etc.) return an error wrapping serial.ErrInvalidConfig. Use errors.As with *serial.ConfigError to get the invalid field, value, and reason:

package main

import (
	"errors"
	"log"

	"github.com/otfabric/go-serial"
)

func main() {
	_, err := serial.Open(&serial.Config{Address: ""})
	if err != nil {
		if errors.Is(err, serial.ErrInvalidConfig) {
			var cfgErr *serial.ConfigError
			if errors.As(err, &cfgErr) {
				log.Printf("invalid config: field=%s value=%v reason=%s",
					cfgErr.Field, cfgErr.Value, cfgErr.Reason)
			}
		}
		return
	}
}

You can also call cfg.Validate() or serial.ValidateConfig(&cfg) before opening.

Use serial.IsUnsupportedBaudRate(err) to detect when the baud rate is not supported on this platform.

Zero-value defaults

Before opening, Open normalizes config: BaudRate(0)→9600, DataBits(0)→8, StopBits(0)→1, Parity("")→none. So you can set only Address and get 9600 8N1.

RS-485

RS-485 options live on Config.RS485. Set RS485.Enabled to true and configure delays and RTS behavior as needed. Support is platform-dependent (e.g. Linux with RS485-capable drivers). The transport API is unchanged; RS-485 is not Modbus-specific.

Supported platforms

  • Linux
  • macOS (Darwin)
  • Windows
  • FreeBSD, NetBSD, OpenBSD

On Windows, any positive baud rate is passed to the driver; acceptance is driver-dependent. On POSIX, supported baud rates are platform-specific (see your OS termios).

Automated tests

Run the test suite with:

go test ./...

Or use the Makefile targets:

make test        # unit tests (shuffle enabled)
make test-race   # race detector
make coverage    # library coverage report (example/ excluded)
make check       # fmt, tidy, vet, lint, tests, race, coverage

Tests do not require physical serial hardware. On Linux, macOS, and BSD, TestReadWrite creates a programmatic PTY loopback via /dev/ptmx and exercises open, read, write, and close. The test skips when PTY creation is unavailable (e.g. restricted environments).

Chaos and fuzz tests (TestChaos*, Fuzz*) inject faults over PTYs: random line fragmentation, hangups mid-stream, signal storms during blocking reads, ports above FD_SETSIZE, write backpressure, random configs and open/close churn. Each logs its seed; reproduce or scale a run with:

SERIAL_CHAOS_SEED=<seed> go test -run TestChaos -v .
SERIAL_CHAOS_ITERATIONS=10 go test -race -run TestChaos .
go test -run '^$' -fuzz FuzzConfigValidate -fuzztime 1m .

For a manual socat loopback, set device paths before testing:

# Terminal 1: socat -d -d pty,raw,echo=0 pty,raw,echo=0
export SERIAL_LOOPBACK_PTY1=/dev/pts/3   # paths from socat output
export SERIAL_LOOPBACK_PTY2=/dev/pts/4
go test -run TestReadWrite ./...

The example/ package is a standalone demo (go run ./example/...); it is excluded from make coverage and from CI coverage via the shared workflow package filter.

Manual loopback testing

For interactive debugging outside the test suite:

Linux and macOS

socat -d -d pty,raw,echo=0 pty,raw,echo=0

On macOS: brew install socat. Use the two PTY paths from socat output with your serial tool or set SERIAL_LOOPBACK_PTY1 / SERIAL_LOOPBACK_PTY2 for TestReadWrite.

Windows


FAQ

How do I open a serial port in Go?

Create a config with serial.DefaultConfig("/dev/ttyUSB0") (or COM3 on Windows), call serial.Open(&cfg), then use Read, Write and Close on the returned port. See the Quick start.

Does go-serial support RS-485?

Yes. Set Config.RS485.Enabled and configure RTS behavior and delays. Support depends on the platform and driver. See RS-485.

What serial settings does Modbus RTU use?

The modbus package provides DefaultRTUConfig, which gives the usual Modbus RTU defaults of 19200 baud, 8 data bits, even parity and 1 stop bit. go-serial only provides the transport. For framing, CRC and master/slave logic use a Modbus library such as go-modbus.

How is it different from goburrow/serial?

go-serial keeps a similar Config and Open shape but adds typed configuration, validation errors, a documented concurrency contract and a Modbus RTU preset. The zero-value defaults changed from Modbus-style 19200 even parity to a generic 9600 8N1. See the migration guide.

Can I list the available serial ports?

Not with go-serial. Pass the device path or COM port name directly. If you need enumeration or USB metadata, go.bug.st/serial and its enumerator package provide it.

Which platforms are supported?

Linux, macOS, Windows, FreeBSD, NetBSD and OpenBSD. See Supported platforms.

How can I test without a physical serial device?

Use a PTY pair created with socat. The test suite also creates a PTY loopback automatically on Linux, macOS and BSD. See Manual loopback testing.


Project structure

Repository layout
go-serial/
├── .                  Public package `serial` — Open, Config, Port
├── modbus/            Modbus RTU serial presets (defaults only)
├── example/           Demo program
├── RELEASE.md         Release history
└── README.md

Platform backends are build-tagged (serial_posix.go, serial_windows.go, …).

Documents: API.md, ARCHITECTURE.md, ERRORS.md, TESTING.md, LIMITATIONS.md, SECURITY.md, CONTRIBUTING.md, RELEASE.md.


Contributing

Bug reports, platform and driver compatibility notes, and pull requests are welcome. Please open an issue to discuss larger changes first.

If go-serial is useful to you, a star on GitHub helps other Go developers find it.


License

This project is licensed under the MIT License. See LICENSE.