flaky-testIssues and PRs involving tests that fail intermittently in CI.Issues and PRs involving tests that fail intermittently in CI.windowsIssues and PRs related to the Windows platform.Issues and PRs related to the Windows platform.workerIssues and PRs related to the worker_threads module and Worker API.Issues and PRs related to the worker_threads module and Worker API.
Description
test-rackspace-win2008r2-x64-4
07:23:03 not ok 535 parallel/test-worker-exit-code
07:23:03 ---
07:23:03 duration_ms: 120.167
07:23:03 severity: fail
07:23:03 exitcode: 1
07:23:03 stack: |-
07:23:03 timeout
07:23:03 ok - 0 exited with 42
07:23:03 ok - 1 exited with 42
07:23:03 ok - 2 exited with 0
07:23:03 ok - 4 exited with 99
07:23:03 Error: ok
07:23:03 at Object.exitWithOneOnUncaught [as func] (c:\workspace\node-test-binary-windows\test\fixtures\process-exit-code-cases.js:47:9)
07:23:03 at MessagePort.parentPort.once (c:\workspace\node-test-binary-windows\test\parallel\test-worker-exit-code.js:23:54)
07:23:03 at Object.onceWrapper (events.js:285:13)
07:23:03 at MessagePort.emit (events.js:197:13)
07:23:03 at MessagePort.onmessage (internal/worker/io.js:68:8)
07:23:03 ok - 3 exited with 1
07:23:03 ok - 5 exited with 0
07:23:03 ok - 6 exited with 97
07:23:03 Error: ok
07:23:03 at Object.changeCodeInExitWithUncaught [as func] (c:\workspace\node-test-binary-windows\test\fixtures\process-exit-code-cases.js:93:9)
07:23:03 at MessagePort.parentPort.once (c:\workspace\node-test-binary-windows\test\parallel\test-worker-exit-code.js:23:54)
07:23:03 at Object.onceWrapper (events.js:285:13)
07:23:03 at MessagePort.emit (events.js:197:13)
07:23:03 at MessagePort.onmessage (internal/worker/io.js:68:8)
07:23:03 Error: ok
07:23:03 at Object.exitWithZeroInExitWithUncaught [as func] (c:\workspace\node-test-binary-windows\test\fixtures\process-exit-code-cases.js:107:9)
07:23:03 at MessagePort.parentPort.once (c:\workspace\node-test-binary-windows\test\parallel\test-worker-exit-code.js:23:54)
07:23:03 at Object.onceWrapper (events.js:285:13)
07:23:03 at MessagePort.emit (events.js:197:13)
07:23:03 at MessagePort.onmessage (internal/worker/io.js:68:8)
07:23:03 ok - 7 exited with 98
07:23:03 ok - 8 exited with 0
07:23:03 ...Reactions are currently unavailable
Metadata
Metadata
Assignees
Labels
flaky-testIssues and PRs involving tests that fail intermittently in CI.Issues and PRs involving tests that fail intermittently in CI.windowsIssues and PRs related to the Windows platform.Issues and PRs related to the Windows platform.workerIssues and PRs related to the worker_threads module and Worker API.Issues and PRs related to the worker_threads module and Worker API.
Activity
[-]Investigate flaky test-worker-exit-code on Windwos CI[/-][+]Investigate flaky test-worker-exit-code on Windows CI[/+]Trott commentedon Jan 31, 2019
https://ci.nodejs.org/job/node-test-binary-windows/23456/COMPILED_BY=vs2017,RUNNER=win2008r2-vs2017,RUN_SUBSET=0/console
test-rackspace-win2008r2-x64-5
Trott commentedon Jan 31, 2019
@nodejs/platform-windows @nodejs/workers @nodejs/testing
addaleax commentedon Jan 31, 2019
I ran a stress test on LinuxOne + 3 Windows-es: https://ci.nodejs.org/job/node-stress-single-test/2145/
Looks like this might be only flaky on win2008 (25/1000) + win2012 (10/1000) but not win2016?
This is the 4th flaky test revolving around exiting workers on Windows, besides #25702, #24005, #23873. If this is an OS-specific problem that occurs only on older versions of Windows, I’m not sure what the best strategy to figure this out is?
gireeshpunathil commentedon Feb 1, 2019
my thinking (not proven with evidence) is that these systems present variance of latency in terms of thread life cycle, disk access and scheduling leading to race at different capacity; not necessarily anything to do with functional differences (which would have caused failures to be more consistent).
I will spend some time next week attempting to recreate one or more these.
worker,etw: only enable ETW on the main thread
worker,etw: only enable ETW on the main thread